7general purpose output, 1 introduction, 2 general purpose output off – Matrix Orbital LK402-25 Legacy User Manual

Page 31: 3 general purpose output on

Advertising
background image

Description

This command will place a bar graph at the specified [Column] with the
specified [Length]. The [Length] is the size in pixels of the bar graph.

NOTES

• A Vertical Bar style must be initialized before this command is executed.
• Bar graphs may be one directional only.

Remembered

No

7

General Purpose Output

7.1

Introduction

General purpose outputs allow you to connect devices, such as LEDs, to the LK402-25 and supply them

with up to 20mA of current at 5V. The LK402-25 has 6 GPOs which are software controlled, with functions
to turn them on/off and set the power state for the next startup.

7.2

General Purpose Output Off

Syntax

Hexadecimal

0xFE 0x56 [Num]

Decimal

254 86 [Num]

ASCII

254 “V” [Num]

Parameters

Parameter

Length

Description

Num

1

GPO number.

Description

This command turns OFF general purpose output [num].

NOTE

OFF means that the output is pulled LOW.

Remembered

Yes

7.3

General Purpose Output On

Syntax

Hexadecimal

0xFE 0x57 [Num]

Decimal

254 87 [Num]

ASCII

254 “W” [Num]

Parameters

Parameter

Length

Description

Num

1

GPO number.

Matrix Orbital

LK402-25

27