6 set debounce time, 7 set auto repeat mode – Matrix Orbital LK402-25 Legacy User Manual
Page 37

Remembered
No
9.6
Set Debounce Time
Syntax
Hexadecimal
0xFE 0x55 [time]
Decimal
254 85 [time]
ASCII
254 “U” [time]
Parameters
Parameter
Length
Description
time
1
Debounce time in increments of
6.554ms (0 - 255).
Description
This command sets the time between key press and key read. All key
types with the exception of latched piezo switches will ’bounce’ for a
varying time, depending on their physical characteristics. The [time]
value is in increments of 6.554ms. The default debounce time for the
module is 8 (about 52ms), which is adequate for most membrane
keypads.
Remembered
Yes
Default
8
9.7
Set Auto Repeat Mode
Syntax
Hexadecimal
0xFE 0x7E [mode]
Decimal
254 126 [mode]
ASCII
254 “~” [mode]
Parameters
Parameter
Length
Description
mode
1
Auto Repeat Mode (0: Resend Key
, 1: Key Up/Down)
Matrix Orbital
LK402-25
33