Flytec 3020 User Manual

Operating instructions flytec 3020

Advertising
background image

Operating instructions FLYTEC 3020

Seite 1 von 2

1. On / Off switch

2. Analog vario display

3. Digital vario display

4. Altitude 1: Absolute altitude

Altitude 2: Relative Altitude / Stopwatch

5. Speed display / Time

Peak value memory

6. Vane wheel sensor socket

rechargeable battery charging socket

7. key UP / START-STOP-RESET

8. key DOWN / zeroing Altitude 2

9. Descent tone / descent alarm key

10. Sound volume key / vario attenuation

11. Changeover key SPEED-TIME-MEMO

12. Changeover key Altitude 1 - Altitude 2

- Chrono

13. REC switch

Starting: On1 or On2 (1). Two independent batteries (rechargeable). The switch should he set to OFF when the unit has switched off automatically.

Battery control: Power voltage is indicated on the analog vario display (2) for approximately 10 seconds and «Po» for power on the digital vario

display. When all the segments in the ascent sector (green) light up, this indicates that the battery which has been switched on has an energy reserve

of 100%.

Inadequate power reserve is indicated continuously when switched on and during operation by the lighting up of one or several segments in the descent

sector (red) and «Po». Please refer to «CHANGEOVER TO RECHARGEABLE BATTERY OPERATION» for BATTERY charging information.

Automatic power down: Power is automatically cut off approx. 30mins. after the unit is last used. The on/off switch must fi rst be set at OFF before

the unit can be used again.

Setting mode: 1. Changeover into adjustment mode is effected by pressing a key (9, 10, 11 or 12) for several (approx. 4) seconds. The corresponding

display will then fl ash intermittently and can be reset.

2. Use the reset key «Up» (7) or «Down» (8) to set the required value. When entering altitude fi gures, the number display can be speeded up by

continuous pressing.

3. Finish by pressing the corresponding original key.

Altimeter: Altitude 1: Absolute altitude. Can be set within weather-dependent tole rances.

Altitude 2: Relative altitude. Can be set whenever required over the whole measure ment range and zeroed at any time by pressing the key «CLEAR

ALTI 2» (8). lt can also be cleared while ALTI 1 is shown on the display.

Pressing the changeover key ALTI 1-ALTI 2 (12) indicates the desired altitude and marks it with an arrow. Pressing the changeover key (12) for several

(approx. 4) seconds will cause the unit to change to the adjustment mode of the altitude currently displayed (see Setting mode).

Altitude gain / loss: Altimeter 2 (ALTI 2) can be used to indicate a gain or loss in altitude, as it can be zeroed at any time using the key «CLEAR ALTI

2 » (8), even while ALTI 1 is displayed.

Analog vario: Fully automatic segment display over the entire range. Individual segments remain displayed until the end of the fi rst scale sector is

reached. They are then deleted from zero in the second scale sector pass again until the end of the second scale sector is reached.

Digital vario: Display over the entire range.

Digital vario attenuation: Changeover into the vario attenuation setting mode is effected by pressing the volume key (10) for several (approx. 4)

seconds (c.f. Setting mode). The following average value computations are possible for the digital vario display:

0 = average value for the last second (4 measurements per second)

5 = average value forthe last 5 seconds

10 = average value for the last 10 seconds

15 = average value for the last 15 seconds

20 = average value for the last 20 seconds

25 = average value for the last 25 seconds

30 = average value for the last 30 seconds

The analog vario display is not attenuated.