Connect the monorails to transformer – LBL Lighting MO Direct Feed Surf Mag Xfmr 600w 120v/12v User Manual

Page 3

Advertising
background image

3

Connect the Monorails to Transformer

Push two Monorail sections completely onto the straight

isolating connectors.

Tighten the M3 set screws firmly with the provided 1.5 MM

Allen wrench.

the set screws which

Do Not Over Tighten

may strip the thread.

M3 SET SCREW

1.5 MM ALLEN
WRENCH

MONORAIL

MONORAIL

STRAIGHT ISOLATING CONNECTOR

POWER FEED
HOUSING

POWER
FEED CAP

SCREW

Remove the power feed caps from the power feed housings.

Completely back out the screw on the power feed caps.

NOTE:

The standoffs should be installed to support the

Monorails while connecting Monorails to the surface
mount transformer. Refer to the instruction provided with
the standoffs.

MONORAIL

POWER
FEED CAP

Place the combined Monorail sections into the standoffs and

power feed housings so that the straight isolating connector

section is located in the middle of the two power feed

housings. Make sure that the Monorail sections are

electrically isolated from each other.

Screw the power feed caps completely to the power feed

housings. Make sure that the power feed caps are not cross

threaded.

Tighten the screw on the power feed caps for proper power

connection.

SCREW

MONORAIL

STRAIGHT ISOLATING CONNECTOR

NOTE:

It is recommended that two people install the

Monorail sections to the standoff and power feed
housings.

1A

2A

1A

2C

1A

2B

1

4

5

2

2

3

3

4

5

6

7

6

7

Advertising