Check the system, Save these instructions, 1a 2a – LBL Lighting MO Rmt Mag Xfmr 600w 277v/12v User Manual

Page 4

Advertising
background image

4

Check the System

COMX X1

X2

X3

X4 COMY Y1

Y2

Y3

Y4

10

11

12

13

PHILLIPS
SCREW

CIRCUIT BREAKER

CIRCUIT
BREAKER

SAVE THESE INSTRUCTIONS!

1

2

3

4

4

4

3

3

7400 Linder Ave, Skokie, IL 60077

800.323.3226 - 847.626.6300

www.generation-brands.com

© 2014 Generation Brands.All rights reserved.The "Genereation Brands"
graphic is a registered trademark of Generation Brands. Generation Brands
reserves the right to change specifications for product improvements without
notification.

A Generation Brands Company

1A

2A

After installing the entire low voltage system, if the
lamps have low intensity, then measure the voltage at
the fixture closest to the power feed contacts with a
voltmeter. The voltmeter should read between 11V - 12V
~AC. If the voltage does not fall in this range, call
Encompass Lighting Group "Technical Support" at 847-
410-4606.

After installing the entire system, operate the system for
five minutes. On the low voltage side, all electrical
connection points should be no more than warm to the
touch. If a connection is hot to the touch, retighten the
connection and check to ensure that the temperature
decreases.

The transformer circuit breaker will trip if there is a short
in the system. After removing the cause of the short, the
circuit breaker needs to be reset to power the system
up.

Replace the transformer cover and tighten the two
Phillips screws on the sides of the transformer.