Samlex America SA-300 User Manual

Page 10

Advertising
background image

3-4. Installation

Before connecting your applications to the inverter, always check the power

draw of your appliances. The inverter can supply surge power for a short time

so as to start up the electrical equipment such as motors, pumps… that need

more power while starting up.

When all the above requirements are checked OK and satisfied and all

connections are made, it’s time to turn on the inverter by switching the power

to ‘ I ’ position. The sine wave filters provide sine wave output voltage when

driven from AC outlet.

To save the battery power, you are highly recommended to turn off the

inverter when it is not used.

DC input voltage status as follows:

Model

DC Input Over

Voltage

DC Input Under

Voltage

Shut-down

Restart

Shut-down

Restart

12V models

15.3

14.3

10.5

12.7

24V models

30.6

28.6

21.0

25.2