Connect DC input terminal to 12V / 24V battery or the other power sources.
【+】represents positive, and【-】represents negative. Reverse polarity
connection will blow the internal fuse and may damage the inverter permanently.

Model

DC Input Voltage

Minimum

Maximum

12 V

10.5

15.0

24 V

21.0

30.0

3-2-4. Use wire # 8 AWG to connect Chassis ground with vehicle chassis.

3-3. Protections Features:

Model

DC Input (VDC)

Over Temperature Protection

Over Voltage

Under

Voltage

Alarm

Under Voltage

INTERIOR

HEAT SINK

Shut-

down

Restart

Shut-

down

Restart

Shut-

down

Restart

Shut-

down

Restart

12 V

15.3V

14.3V

11.0V

10.2V

12.7V

70

45

90

60

24 V

30.6V

28.8V

22.0V

20.3V

25.2V