3-2-3. DC Input Terminal:
Connect DC input terminal to 12V / 24V / 48V battery or the other
power sources.
【+】
represents positive, and【-】represents negative. Reverse
polarity connection will blow the internal fuse and may damage the
inverter permanently.
Model
DC Input Voltage
Minimum
Maximum
12 V
10.5
15.0
24 V
21.0
30.0
48 V
42.0
60.0
3-2-4. Use wire # 8 AWG to connect Chassis ground with vehicle chassis.
3-3. Protections Features:
Model
DC Input (VDC)
Over Temperature Protection
Over Voltage
Under
Voltage
Alarm
Under
Voltage
INTERIOR
HEAT SINK
Shut-
down
Restart
Shut-
down
Restart
Shut-
down
Restart
Shut-
down
Restart
12 V
15.3V 14.3V
11.0V
10.2V
12.7V
70℃
45℃
90℃
60℃
24 V
30.6V 28.6V
22.0V
20.3V
25.2V
48V
61.0V 57.2V
44.0V
40.8V
49.7V
WARNING!
Operating the inverter without a proper ground
Connection may cause an electrical hazard.