3-2-3. DC Input Terminal:
Connect DC input terminal to 12V / 24V / 48V battery or the other
power sources.
【+】represents positive, and【-】represents negative. Reverse
polarity connection will blow the internal fuse and may damage the
inverter permanently.
DC Input Voltage
Model
Minimum
Maximum
12 V
10.5
15.0
24 V
21.0
30.0
48 V
42.0
60.0
3-2-4. Use wire # 8 AWG to connect Chassis ground with vehicle chassis.
3-3. Protections Features:
DC Input (VDC)
Over Temperature Protection
Over Voltage
Under
Voltage
INTERIOR
HEAT SINK
Model
Shut-
down
Restart
Under
Voltage
Alarm
Shut-
down
Restart
Shut-
down
Restart
Shut-
down
Restart
12
V 15.3 14.3 11.0 10.2 12.7
24
V 30.6 28.8 22.0 20.3 25.2
48V
61.0 58.1 44.0 40.8 49.7
70℃ 45℃
90℃ 60℃
WARNING!
Operating the inverter without a proper ground
Connection may cause an electrical hazard.
15