background image

Load cannot be

operated
+
info LED flashes

red
+
. green LED

flashes

load output is switched off

due to excessive battery

voltage

•

the load output automatically

switched on again as soon as

the battery voltage lies within

the permissible range

incorrect grounding

•

check the grounding

external charging source is

not voltage-limited

•

check the external charging

source
if necessary, switch off exter-

nal charging sources

Load cannot be

operated
+
info LED illumi-

nates green

defective load or installation

error

•

connect load correctly

replace load

Battery is not

charged

solar module not connected

•

connect the solar module

solar module connected with

incorrect polarity

•

connect the solar module

with the correct polarity

short circuit at solar module

input

•

correct the cause of the short

circuit

incorrect solar module

voltage

•

use a solar module of the

specified voltage

solar module defective

•

replace the solar module

Battery display

jumps quickly

large pulse current

•

tune the current consump-

tion to match the battery

capacity

battery is defective

•

replace the battery