B.1.2 cr10x example program, B.1.2 – Campbell Scientific 014A Met One Wind Speed Sensor User Manual
Page 26

Appendix B. Example Programs
B.1.2 CR10X Example Program
;{CR10X}
*Table 1 Program
01: 5.0000 Execution Interval (seconds)
1: Batt Voltage (P10)
1: 1
Loc [ Batt_Volt ]
2: Pulse (P3)
1: 1
Reps
2: 1
Pulse Channel 1
3: 22
Switch Closure, Output Hz
4: 2
Loc [ WS_ms ]
5: 0.8
Multiplier
6: 0.447
Offset
3: If (X<=>F) (P89)
1: 2
X Loc [ WS_ms ]
2: 4
<
3: 0.448
F
4: 30
Then Do
4: Z=F x 10^n (P30)
1: 0
F
2: 0
n, Exponent of 10
3: 2
Z Loc [ WS_ms ]
5: End (P95)
6: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 60
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
7: Set Active Storage Area (P80)
1: 1
Final Storage Area 1
2: 101
Array ID
8: Real Time (P77)
1: 1220
Year,Day,Hour/Minute (midnight = 2400)
9: Average (P71)
1: 1
Reps
2: 2
Loc [ WS_ms ]
B-2