2 cr10x example program – Campbell Scientific 03001-L R.M. Young Wind Sentry Set User Manual
Page 14

R.M. Young Wind Sentry
'Call Data Tables and Store Data
CallTable(Table1)
NextScan
EndProg
5.4.2 CR10X Example Program
;{CR10X}
*Table 1 Program
01: 5.0000 Execution
Interval
(seconds)
1: Batt Voltage (P10)
1: 1
Loc [ Batt_Volt ]
;03001 or 03101 RM Young Wind Sentry Wind Speed Sensor measurement - WS_ms:
2: Pulse (P3)
1: 1
Reps
2: 1
Pulse
Channel
1
3: 21
Low Level AC, Output Hz
4: 2
Loc [ WS_ms ]
5: 0.75
Multiplier
6: 0.2
Offset
3: If (X<=>F) (P89)
1: 2
X Loc [ WS_ms ]
2: 4
<
3: 0.21
F
4: 30
Then
Do
4: Z=F x 10^n (P30)
1: 0
F
2: 0
n, Exponent of 10
3: 2
Z Loc [ WS_ms ]
5: End (P95)
;03001 or 03301 RM Young Wind Direction Sensor measurement - WindDir:
6: Excite-Delay (SE) (P4)
1: 1
Reps
2: 5
2500 mV Slow Range
;5000 mV(slow/60hz) range for CR23X, 21X, or CR7
3: 1
SE
Channel
4: 1
Excite all reps w/Exchan 1
5: 2
Delay (0.01 sec units)
6: 2500
mV
Excitation
;5000 mV for CR23X, 21X, or CR7
7: 3
Loc [ WindDir ]
8: 0.142
Multiplier ;0.071 for CR23X, 21X, or CR7
9: 0
Offset
10