Campbell Scientific 4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules User Manual
Page 33
4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules (TIM)
11: Z=X-Y (P35) ;
Subtract zeroed value from measurement.
 1: 1 -- X Loc [ mVPerVG01 ] 
 2: 17 -- Y Loc [ mVPerVZ01 ] 
 3: 33 Z Loc [ Vr_1 ] 
 12: Z=X*F (P37) 
 1: 33 X Loc [ Vr_1 ] 
 2: -2 F 
 3: 34 Z Loc [ One_2Vr ] 
 13: Z=X+F (P34) 
 1: 34 X Loc [ One_2Vr ] 
 2: 1000 F 
 3: 34 Z Loc [ One_2Vr ] 
 14: Z=X/Y (P38) 
 1: 33 X Loc [ Vr_1 ] 
 2: 34 Y Loc [ One_2Vr ] 
 3: 35 Z Loc [ Vr_1_2Vr ] 
 15: Z=X/Y (P38) 
 1: 35 X Loc [ Vr_1_2Vr ] 
 2: 36 -- Y Loc [ AdjGF01 ] 
 3: 52 -- Z Loc [ uStrain01 ] 
 16: Z=X*Y (P36) 
 1: 52 -- X Loc [ uStrain01 ] 
 2: 68 Y Loc [ Number4e3 ] 
 3: 52 -- Z Loc [ uStrain01 ] 
17: End (P95)
18: If Flag/Port (P91) 
 1: 12 Do if Flag 2 is High 
 2: 30 Then Do 
 19: If time is (P92) 
 1: 0 Minutes (Seconds --) into a 
 2: 1 Interval (same units as above) 
 3: 2 Call Subroutine 2 ; 
Outputs data to FinalStorage.
20: End (P95) 
*Table 2 Program 
 02: 0 
*Table 3 Subroutines 
1: Beginning of Subroutine (P85) ; 
Measures ZeroOffset strain reading and sets GF
1: 1 Subroutine 1
2: Do (P86) ;
Setup so Subroutine does not get called again.
1: 11 Set Flag 1 High
3: Z=F (P30) ;
Lead Length Resistance per 100 feet.
1: 2.5 F ;
0.025 Ohms/Foot for 24 gauge copper stranded wire.
 2: 0 Exponent of 10 
 3: 69 Z Loc [ LeadOhms ] 
4: Bulk Load (P65) ;
Load lead length of the gages in 100s of feet:
1: 3.0 F
;
Gage01
2: 4.4 F ;
Gage02
3: 8 F ;
Gage03
4: 12 F ;
Gage04
5: 14 F ;
Gage05
6: 19 F ;
Gage06
7: 15 F ;
Gage07
8: 13 F ;
Gage08
9: 70 Loc [ LeadFt01 ]
27