1. al200 dimensions – Campbell Scientific AL200 ALERT2 Encoder, Modulator, and Sensor Interface User Manual
Page 12

AL200 ALERT2 Encoder, Modulator, and Sensor Interface
FIGURE 6-1. AL200 dimensions
Configuration
This device is designed to easily be configured through the graphical
interface, Device Configuration Utility. When used as a stand-alone
device, no programming is required.
The device driver for the AL200 must be installed on your
computer before you can connect to the AL200 via USB. See
Appendix E, AL200 USB Driver Installation Instructions, for
instructions on installing the device driver.
When used as a datalogger peripheral, the same Device Configuration
Utility software is used to configure the AL200. Additional steps will be
required to program the datalogger to interface with the AL200.
USB
Micro-B receptacle
Can power AL200 during configuration; not suitable for operational
current draws
Requires FTDI Virtual COM Port (VCP) driver installation
CS I/O Port
SDC 7, 8, 10, 11
ALERT2 or ALERT-concentration
AL200 is NOT powered over CS I/O
Multiplexed with integrated sensor I/O
NOTE