Mounting in enclosure door, Shipping kit, Hardware – Campbell Scientific CD294 DataView Dual Line Data Display User Manual

Page 11

Advertising
background image

DataView (CD294) Dual Line Data Display

5. Mounting in Enclosure Door

Use the template provided to mark out the four mounting holes and cut-
out for the CD294. Drill the four corner holes using a 4.5 mm drill and
cut out the mounting hole using a jig-saw or nibbler. Use the screws and
nuts provided to attach the CD294, ensuring that the rubber o-ring is
located correctly in the o-ring groove to provide sealing.

6. Shipping Kit

The CD294 DataView Shipping Kit includes:

1. CD294 DataView display with data cable
2. Custom CD294 programming cable
3. Compact Disc containing PC294 programming software, CD294 Manual,

SDS511 manual and example software

4. CD294 MountingTemplate
5. 4 x Mounting screws, nuts, metal washers and sealing washers
6. 2 mm silicon o-ring

7. Hardware

SPECIFICATIONS

Physical
Width: 130

mm

Height: 100

mm

Depth: 25

mm

Weight: 150

g

Supply Requirements: 5 VDC (Powered from datalogger)

Power
Current consumption:

Operating: 5.5 mA typical while display is active

Quiescent:

<100

μA

7