CRS451/CRS456 Submersible Water-Level Recording Sensor

6.5 Other Installations

The CRS451/CRS456 can be installed in any position; however, when it leaves

the factory it is tested in the vertical position. There will be an offset error if

not installed vertically; contact Campbell Scientific for more information.

Strapping the transducer body with tie wraps or tape will not hurt it.

6.6 Battery Voltage Reading

The voltage of the lithium ion battery used in the CRS451/CRS456 will

abruptly decrease at the end of the battery’s useful life, which makes predicting

remaining battery life difficult by measuring battery voltage alone. Knowing

the energy consumption of the CRS451/CRS456 while in operation, HydroSci

displays a predicted remaining battery life by combining an estimate of the

energy consumed based on the totalized measurements since new and direct

battery measurements. For this reason, if the battery is removed from the

CRS451/CRS456 anytime during deployment and then replaced, HydroSci will

assume a fresh battery was added to the device and the estimated remaining

battery life will be overstated.

For similar reasons, if the operating system is upgraded or sent to the

CRS451/CRS456, the estimated remaining battery life will also be exaggerated

by HydroSci.

6.7 Attaching Suspension Cable to CRS451/CRS456

Attach the split ring to the CRS451 cap.

6