2 cr800, cr850, and cr1000 programs – Campbell Scientific CS420 and CS425 PDCR 1830-8388 Pressure Transducer User Manual
Page 12

CS420-L and CS425-L Pressure Transducers
6.2 CR800, CR850, and CR1000 Programs
6.2.1 BrFull Instruction (4-Wire Full Bridge Measurement)
'CR1000, CR800, CR850
'4wire configuration
Public Depth_Ft
DataTable (WtrData,1,-1)
DataInterval
(0,15,Min,10)
Sample
(1,Depth_Ft,FP2)
EndTable
BeginProg
Scan
(15,Min,0,0)
BrFull (Depth_Ft,1,mV2500,1,Vx1,1,2500,True ,True ,0,250,2.3529,-0.49)
CallTable
WtrData
NextScan
EndProg
6.2.2 BrFull6W Instruction (6-Wire Full Bridge Measurement)
'CR1000, CR800, CR850
'6wire configuration
Public Depth_Ft
DataTable (WtrData,1,-1)
DataInterval
(0,15,Min,10)
Sample
(1,Depth_Ft,FP2)
EndTable
BeginProg
Scan
(15,Min,0,0)
BrFull6W (Depth_Ft,1,mV2500,mV25,1,Vx1,1,2500,True ,True ,0,250,2.3529,-0.49)
CallTable
WtrData
NextScan
EndProg
8