Specifications, 1. cs451 nose cone options – Campbell Scientific CS451/CS456 Pressure Transducer User Manual
Page 16

CS451/CS456 Submersible Pressure Transducer
FIGURE 5-1. CS451 nose cone options
6. Specifications
Features:
•
Output acceptable for recording devices with SDI-12 or RS-232
capability including Campbell Scientific dataloggers
•
Quality construction that ensures product reliability
•
Rugged stainless steel or titanium case that protects piezoresistive
sensor
•
Fully temperature compensated
•
Low power sleep state between measurements that reduces power
consumption
•
Weighted nose cone offered that adds 0.2 kg (7.4 oz) to the
transducer’s weight. Additional weight makes submersion of the
transducer easier
•
Compatible with Campbell Scientific CRBasic dataloggers:
CR200(X) series, CR800 series, CR1000, CR3000, and CR5000.
Also compatible with Edlog dataloggers: CR500, CR510, CR10(X),
and CR23X
Power Requirements:
5 to 18 Vdc
Power Consumption:
Quiescent current < 50 µA
Measurement/Communication Current: 8 mA
for 1-s measurement
Maximum Peak Current: 40 mA
Measurement Time:
Less than 1.5 s
Outputs:
SDI-12 (version 1.3) 1200 bps
RS-232 9600 bps
Standard Nose Cone
Weighted Nose Cone
1/4 inch NPT Nose Cone
6