Table 4-2 and table 4-3 – Campbell Scientific CS475, CS476, and CS477 Radar Water Level Sensor User Manual

Page 11

Advertising
background image

CS475, CS476, and CS477 Radar Water Level Sensor

TABLE 4-2. Radiation Beam Spread for CS475

(10° Beam Angle)

Distance in Meters

Diameter of Footprint in Meters

1 0.18

5 0.87

10 1.76

15 2.64

20 3.53

TABLE 4-3. Radiation Beam Spread for CS476/CS477

(8° Beam Angle)

Distance in Meters

Diameter of Footprint in Meters

1 0.14

5 0.70

10 1.41

15 2.11

20 2.81

30 4.216

70 (CS477 only)

9.84

3. Securely mount the sensor.

4. Use a user-supplied bubble level or the 25619 bubble level to make certain

the antenna horn is aligned within 1° of vertical. The cap needs to be
removed when using the 25619. If the antenna is not vertical, a
trigonometric measurement error can occur with respect to the water. The
maximum range is reduced because of the off-axis return signal.

5. Orient the sensor such that one of its polarization markings is aligned

towards the wall or pier (see FIGURE 4-1 and TABLE 4-4).

3