FIGURE 4-4. CSAT3 coordinate system and original noncaptive

mounting hardware (s/n 0107 to 0630)

4.3 Leveling

Over flat level terrain, adjust the anemometer head so that the bubble within

the level is in the bullseye. Over sloping terrain, adjust the anemometer head

so that the horizontal surface that the bubble level is mounted on is parallel to

the terrain. Firmly grasp the sonic anemometer block, loosen the bolt

underneath the block, and adjust the head accordingly. Finally, tighten the bolt

with a 9/16-inch wrench.

4.4 Fine Wire Thermocouple

A fine wire thermocouple (model FW05 and FWC-L35) can be mounted to the

side of the anemometer block to measure temperature fluctuations. Attach the

female connector from the FWC-L35 to the side of the anemometer with the

short screw (#2-56 0.437 inch, pn 3514) that was provided with the

thermocouple cover. Insert the male connector of the FW05 into the female

connector of the FWC-L35. Finally, attach the thermocouple cover to the

anemometer block, using the thumb screw, so that both the FW05 and FWC-

L35 connectors are covered.

5. Wiring

There are four military style connectors on the CSAT3 electronics box. They

are labeled as +12V SDM, RS-232, Transducer Head, and Analog Output.

Connect the cable from the anemometer head to the electronics box labeled

Transducer Head. The anemometer head cable is 2.13 m (7 ft) in length. Each

of the signal cables is 7.62 m (25 ft) in length. Connect the appropriate signal

cable to the electronics box. See the TABLE 5-1 through TABLE 5-8 for

details on the wire color scheme.