Campbell Scientific CSAT3 3-D Sonic Anemometer User Manual
Page 42

CSAT3 Three Dimensional Sonic Anemometer
17: Real Time (P77)
1: 110
Day,Hour/Minute (midnight = 0000)
18: Resolution (P78)
1: 1
High Resolution
19: Sample (P70)
1: 3
Reps
2: 13
Loc [ wnd_spd_a ]
20: Sample (P70)
1: 1
Reps
2: 17
Loc [ csat_dir ]
21: Average (P71)
1: 4
Reps
2: 1
Loc [ Ux ]
22: Standard Deviation (P82)
1: 4
Reps
2: 1
Sample Loc [ Ux ]
23: Totalize (P72)
1: 7
Reps
2: 20
Loc [ smpls ]
*Table 2 Program
02: 0
Execution Interval (seconds)
*Table 3 Subroutines
;Configure CSAT3.
;
1: Beginning of Subroutine (P85)
1: 1
Subroutine 1
;Check the diagnostic word for lost trigger condition.
;Set Flag 1 low to reconfigure the CSAT3 if it is in a
;lost trigger state.
;
2: If (X<=>F) (P89)
1: 5
X Loc [ diag ]
2: 1
=
3: 61440
F
4: 21
Set Flag 1 Low
;Configure the CSAT3. This is done the first time
;through Table 1 or if the CSAT3 loses the trigger.
;
3: If Flag/Port (P91)
1: 21
Do if Flag 1 is Low
2: 30
Then Do
32