Campbell Scientific EnviroSCAN Sentek Water Content Profile Probe User Manual

Page 13

Advertising
background image

EnviroSMART

TM

Soil Water Content Profile Probes

;Wiring:

EnviroSMART / EasyAG 12 Volts (Pin 1) -------- CR10X 12 V

;

EnviroSMART / EasyAG Ground (Pin 2) ------- CR10X Ground

;

EnviroSMART / EasyAG Signal (Pin 3) --------- C7


;

Rain Gage Pulse Out -------------------------------- CR10X P2

; Rain

Gage

Ground----------------------------------- CR10X

Ground


;{CR10X}
;
*Table 1 Program
01: 30

Execution

Interval

(seconds)


;Load Scaled Frequency to Water Content Co-effecients

a = .1957
b = .404
c = .02852

;Preload missing sensor error

1: Beginning of Loop (P87)
1: 0

Delay

2: 8

Loop

Count


2: Z=F x 10^n (P30)

1: -1000

F

2: 0

n, Exponent of 10

3: 1

-- Z Loc [ ES1_SF_1 ]


3: Z=F x 10^n (P30)

1: -1000

F

2: 0

n, Exponent of 10

3: 17

-- Z Loc [ ES1_VIC_1 ]


4: End (P95)

;Measure water content scaled frequencies (SF)

5: Beginning of Loop (P87)
1: 0

Delay

2: 5

Loop

Count


;See Appendix E for other SDI-12 commands

6: SDI-12 Recorder (P105)

1: 0

SDI-12

Address

2: 0

Start

Measurement

(aM0!)

3: 7

Port

4: 1

Loc [ ES1_SF_1 ]

5: 1.0

Mult

6: 0

Offset

9

Advertising