Campbell Scientific EnviroSCAN Sentek Water Content Profile Probe User Manual
Page 14

EnviroSMART
TM
Soil Water Content Profile Probes
7: If (X<=>F) (P89)
1: 1
X Loc [ ES1_SF_1 ]
2: 2
<>
3: 0
F
4: 31
Exit Loop if True
8: End (P95)
;Measure salinity volumetric ion content (VIC)
9: Beginning of Loop (P87)
1: 0
Delay
2: 5
Loop
Count
10: SDI-12 Recorder (P105)
1: 0
SDI-12
Address
2: 2
Start
Measurement
(aM2!)
3: 7
Port
4: 17
Loc [ ES1_VIC_1 ]
5: 1.0
Mult
6: 0
Offset
11: If (X<=>F) (P89)
1: 17
X Loc [ ES1_VIC_1 ]
2: 2
<>
3: 0
F
4: 31
Exit Loop if True
12: End (P95)
;Load measurement failure errors
13: If (X<=>F) (P89)
;Measurement of 0 at 1st sensor
1: 1
X Loc [ ES1_SF_1 ]
;indicates an inactive probe.
2: 1
=
;
3: 0
F
4: 30
Then
Do
14: Z=F x 10^n (P30)
;Set 1st sensor reading to -99999
1: -99999 F
2: 0
n, Exponent of 10
3: 1
Z Loc [ ES1_SF_1 ]
15: End (P95)
16: Beginning of Loop (P87)
;Loop to set error codes
1: 0
Delay
2: 8
Loop
Count
10