Model HFP01SC Self-Calibrating Soil Heat Flux Plate

11: Beginning of Loop (P87)
1: 0

Delay

2: 6

Loop Count


;Use data from the larger measurement range.
;
12: If (X<=>F) (P89)
1: 7 --

X Loc [ shf_mV_1 ]

2: 4

<

3: -99990 F
4: 30

Then Do


13: Z=X (P31)
1: 44 --

X Loc [ shf_mV_1a ]

2: 7 --

Z Loc [ shf_mV_1 ]


14: End (P95)

;Apply custom calibration to raw soil heat flux measurement.
;
15: Z=X*Y (P36)
1: 7 --

X Loc [ shf_mV_1 ]

2: 13 --

Y Loc [ cal_1 ]

3: 1 --

Z Loc [ shf_1 ]


16: End (P95)

;Output data.
;
17: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 20

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


18: Real Time (P77)^25251
1: 0110

Day,Hour/Minute (midnight = 0000)


19: Resolution (P78)
1: 1

High Resolution


;Do not include that calibration data in the soil heat flux.
;
20: If Flag/Port (P91)
1: 18

Do if Flag 8 is High

2: 19

Set Intermed. Proc. Disable Flag High (Flag 9)


21: Average (P71)^21989
1: 6

Reps

2: 1

Loc [ shf_1 ]


22: Do (P86)
1: 29

Set Intermed. Proc. Disable Flag Low (Flag 9)


23: Sample (P70)^21779
1: 6

Reps

2: 13

Loc [ cal_1 ]


;Add other processing here.

;Call calibration routine.
;
24: Do (P86)
1: 8

Call Subroutine 8


*Table 2 Program
02: 0

Execution Interval (seconds)

19