4.1 Wiring SDM Devices

Before connecting the SDM signal cable to the terminals, strip the wire
insulation back to expose ¼ inch of bare wire. Feed the cable through the
bulkhead fitting. Neatly separate the five wires into the following order, SDM
data, SDM clock, SDM enable, SDM ground, and SDM shield.

FIGURE 1. HUB-SDM5 connecting four SDM devices to a datalogger.

Sealed Bulkhead fitting

To CSAT3 #1

To CSAT3 #2

To LI-7500 #2

To LI-7500 #1

To Datalogger