2 wiring sdi-12 devices – Campbell Scientific HUB-SDM5 Junction Box for SDMs User Manual

Page 7

Advertising
background image

HUB-SDM5

3

FIGURE 2. HUB-SDM5 terminal strip connecting four SDM devices to a datalogger.

4.2 Wiring SDI-12 Devices

Before connecting the SDI-12 signal/power cable to the terminals, strip the
wire insulation back to expose ¼ inch of bare wire. Feed the cable through the
bulkhead fitting. Neatly separate the four wires into the following order, SDI-
12 data, SDI-12 power, SDI-12 ground, SDI-12 shield.

FIGURE 3. HUB-SDM5 connecting three SDI-12 devices

to a datalogger.

To SDI-12 sensor#1

To SDI-12 sensor#2

To SDI-12 sensor#3

SDM Devices

Datalogger or second
HUB-SDM5

SDM Data

SDM Clock

SDM Enable

SDM Ground

SDM Shield

Sealed

Bulkhead

Fitting

To

Datalogger

Advertising