1 station setup – Campbell Scientific LNDB LoggerNet Database Software User Manual

Page 15

Advertising
background image

LNDB

3.1 Station Setup

When a station is highlighted in the left tree, the Station Setup screen is shown.
On the Station Setup screen, tables can be enabled/disabled for storage by
selecting/deselecting the check boxes next to the table names.

A conflict exists for a table when datalogger columns do not match database
columns.

If in "Stop Storing Data" mode (see Section 4.0 Options) and conflicts exist, an
icon is placed next to the table with the conflict. Also a larger icon with bold
text stating there are conflicts is placed at the top of the station setup screen.
To resolve a conflict, right-click on the table name on the right side of the
screen and select Resolve. This brings up the Resolve Table dialog box which
allows you to resolve the conflict. (For more information on resolving a
conflict, see Section 5.)

9