Wiring – Campbell Scientific NR-LITE-L Kipp and Zonen Net Radiometer User Manual
Page 12

NR-LITE Net Radiometer
4. Wiring
The NR-LITE can be measured with a differential or single-ended channel on
the datalogger; a differential channel is recommended.
White Radiation
Signal
Green Signal
Reference
Clear
Shield
(User supplied jumper wire for differential measurement only)
FIGURE 7. NR-Lite to Datalogger Connections
TABLE 1. Datalogger Connections for Differential Measurement
Function
Color
CR10X,CR510
CR23X,
21X, CR7
CR800,
CR850,
CR1000,
CR3000,
CR5000
Radiation Signal
White
Differential H
Differential H Differential
H
Signal Reference
Green
Differential L
Differential L
Differential L
Jumper
to
AG
Shield Clear G
TABLE 2. Datalogger Connections for Single-Ended Measurement
Function
Color
CR10X,CR510
CR23X,
21X, CR7
CR800,
CR850,
CR1000,
CR3000,
CR5000
Radiation Signal
White
S.E. Channel
S.E. Channel
S.E. Channel
Signal Reference
Green
AG
Shield Clear G
8