Campbell Scientific NR-LITE-L Kipp and Zonen Net Radiometer User Manual
Page 15

NR-LITE Net Radiometer
5.3.2 CR1000 Example Program with Wind Speed Correction
Shown below is an example program written for the CR1000 datalogger.
Besides measuring the NR-LITE, the program also measures wind speed and
applies the correction factor as described in Section 1.4. Average net radiation
and wind speed are output every hour.
NR-LITE wiring for Example 2
Color
Function
Example CR1000 Program
Channels Used
White Radiation
Signal
2H
Green Signal
Reference
2L
Jumpered to
Clear Shield
'CR1000
'Declare Variables and Units
Dim WindCor_7
Public BattV
Public WS_ms
Public WindDir
Public NR_Wm2
Public CNR_Wm2
Units BattV=Volts
Units WS_ms=meters/second
Units WindDir=Degrees
Units NR_Wm2=W/m^2
Units CNR_Wm2=Watts/meter^2
'Define Data Tables
DataTable(Table1,True,-1)
DataInterval(0,60,Min,10)
Average(1,WS_ms,FP2,False)
Sample(1,WindDir,FP2)
Average(1,NR_Wm2,FP2,False)
Average(1,CNR_Wm2,FP2,False)
EndTable
DataTable(Table2,True,-1)
DataInterval(0,1440,Min,10)
Minimum(1,BattV,FP2,False,False)
EndTable
'Main Program
BeginProg
Scan(5,Sec,1,0)
'Default Datalogger Battery Voltage measurement BattV
Battery(BattV)
11