PConnectCE for the Pocket PC Handhelds

Flags/Ports

The datalogger's ports and flags can be viewed and toggled from the
Flags/Ports tab. All of the flags and ports in the datalogger are displayed on
the screen. If a flag or port is High, a check mark will appear in the box beside
the port or flag. If a flag or port is low, the box will be empty.

To change the state of a port or flag, touch the box for that port or flag. There
may be a small time lag between when the box is touched and when the state of
the port or flag appears to change.

Flags and Ports for CR510PB, CR10XPB, and CR23XPB
dataloggers also can be viewed and toggled from the
Measurements window.

NOTES

CR200 Series dataloggers do not have Flags or Ports which can
be toggled.

Flags are displayed for the CR1000, CR800/850, and CR3000
only if the datalogger program has a Public variable array
defined, with the name of flag (i.e., Flag (4)). Any element in
the Flag array that is subsequently Aliased will not show up in
the list of Flags. Its value can be changed from the Numeric
Monitor if needed.