Campbell Scientific SDM-CD16AC 16-Channel ac/dc Relay Controller User Manual

Page 14

Advertising
background image

SDM-CD16AC 16 Channel AC/DC Controller

default, minimum allowable, and maximum bit period for each of our CRBasic
dataloggers.

TABLE 3. Bit Period Values


Datalogger

Default
Bit Period

Minimum Allowable
Bit Period

Maximum
Bit Period

CR800, CR850 26.04

μsec 8.68

μsec

2.2 msec

CR1000

26.04

μsec 8.68

μsec

2.2 msec

CR3000

26.04

μsec 8.68

μsec

2.2 msec

CR5000

30

μsec 8

μsec

3 msec

The equation used to calculate the bit rate depends on the datalogger used.
The datalogger will round down to the next faster bit rate.

Equation for CR800, CR850, and CR1000:

bit_rate=INT((k*72)/625)*Resolution

Where:
k= the value entered in BitPeriod

Resolution=8.68 microseconds

Equation for CR3000:

bit_rate=INT((k*144)/625)*Resolution

Where:
k= the value entered in BitPeriod
Resolution= 4.34

μsec.

Equation for CR5000:

bit_rate=INT(k*20)*Resolution

Where:
k= the value entered in BitPeriod
Resolution=50 nsec.

10