Campbell Scientific SDM-CVO4 4-Channel Current/Voltage Output Module User Manual

Page 23

Advertising
background image

SDM-CVO4 4-Channel Current/Voltage Output Module

; Measure the wind direction from a potentiometer windvane

2: Excite-Delay (SE) (P4)
1: 1

Reps

2: 14

1000 mV, Fast Range

3: 1

SE

Channel

4: 1

Excite all reps w/Exchan 1

5: 1

Delay (units 0.01 sec)

6: 1000

mV

Excitation

7: 2

Loc [ WindDir ]

8: 0.357

Mult ; Scale to angle in degrees

9: 0.0

Offset


; Measure air temperature from a 107 probe

3: Temp (107) (P11)
1: 1

Reps

2: 2

SE

Channel

3: 31

Excite all reps w/E1, 50Hz, 10ms delay

4: 3

Loc [ AirT ]

5: 1.0

Mult ; Scale to degrees C

6: 0.0

Offset


; Measure solar radiation from an SP-Lite

4: Volt (SE) (P1)
1: 1

Reps

2: 32

50 mV, 50 Hz Reject, Slow Range

3: 3

SE

Channel

4: 4

Loc [ Radiation ]

5: 100

Mult

6: 0.0

Offset


; Now output data in the normal way to final storage

5: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 1

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


6: Real Time (P77)
1: 110

Day,Hour/Minute (midnight = 0000)


7: Wind Vector (P69)
1: 1

Reps

2: 0

Samples per Sub-Interval

3: 0

S, é1, & е(й1) Polar

4: 1

Wind Speed/East Loc [ WindSpeed ]

5: 2

Wind Direction/North Loc [ WindDir ]


8: Average (P71)
1: 2

Reps

2: 3

Loc [ AirT ]


; Now the code to scale the values and update the SDM-CVO4

19

Advertising