Sp50-l/sp85-l solar panel – Campbell Scientific SP50-L/SP85-L Solar Panel User Manual

Page 20

Advertising
background image

SP50-L/SP85-L Solar Panel

CHG

CHG

G

CHG

SOLAR

CK BATT

OFF

ON

O

I

G

G

12V

12V

To Solar Panel

CH200

Battery

CR1000 Datalogger

FIGURE 3-17. CH200 wired to solar panel, CR1000, and battery

3.5 Installation of Morningstar SunSaver SS-10-12V Regulator

1. Using the supplied mounting hardware, install the Morningstar SunSaver

SS-10-12V regulator (CSI p/n 18529) on the mounting plate of an
environmental enclosure (see FIGURE 3-18).

2. If using deep cycle marine battery along with the SP50 or SP85 solar

panels, install Battery Terminal Strip Adapters (CSI p/n 4386) to each
terminal of the user-supplied deep cycle battery as shown in FIGURE
3-19.

3. Using the spade terminated ends of the supplied red and black power

cables, secure the black wire to terminal lug #1 marked battery (–) on the
regulator. Connect the pigtailed end of the black cable to the “charge”
terminal on the Battery Terminal Strip Adapter installed on the battery’s
negative terminal. Secure the red wire to terminal lug #2 marked battery
(+) on the regulator. Connect the pigtailed end of the red cable to the
“charge” terminal on the Battery Terminal Strip Adapter installed on the
battery’s positive terminal. With the battery connected and no solar panel
input, the green LED on the regulator marked CHARGING SHOULD
NOT
be on.

4. Connect the black (–) wire from the solar panel power cable to terminal

lug #3 marked solar (–) on the regulator. Connect the red (+) wire from

14

Advertising