18. morningstar’s, Sunsaver, Ss-10-12v regulator mounted on – Campbell Scientific SP50-L/SP85-L Solar Panel User Manual

Page 21: An enclosure backplate

Advertising
background image

SP50-L/SP85-L Solar Panel

the solar panel power cable to terminal lug #4 marked solar (+) on the
regulator. If using a sealed rechargeable battery, such as our BP24, BP84,
or PS84, then verify that the metal jumper is installed to configure the
regulator to recharge sealed rechargeable batteries (see FIGURE 3-18). If
using a flooded battery (e.g., deep cycle marine battery), then remove the
jumper
. Also note that no connections are made on the load terminals of
the regulator for this application (see FIGURE 3-18).

5. If charge current is available from the solar panel, the green LED on the

regulator marked CHARGING WILL LIGHT UP. This will verify
proper operation and wiring of the regulator.

6. To supply power to the system, connect the power leads from dataloggers

and sensors to the “load” terminals on the Terminal Strip Adapters
installed on the battery terminals, positive leads to positive terminal, and
negative leads to negative terminal of the battery.

The Morningstar SunSaver SS-10-12V regulator is shipped with
the jumper INSTALLED. If you are using flooded batteries,
such as a deep cycle marine battery, REMOVE the jumper
before installing the regulator.

NOTE

M O R N I N G S T A R

S O L A R C O N T R O L L E R SS-1--12V

Nominal Rating
12 Volts dc
Solar In 10A
Load 10A

See Operator’s
Manual

R

emove

Jumper
Wire for
Flooded
Battery

UN AVER-

10

S S

CHARGING

TEMP SENSOR

!

SOLAR

BATTERY

LOAD

SEALED

OR

FLOODED

SELECT

4

3

2

1

5

6

12V

FIGURE 3-18. Morningstar’s SunSaver SS-10-12V Regulator mounted

on an enclosure backplate

15

Advertising