Maintenance, Battery, Sp50-l/sp90-l solar panel – Campbell Scientific SP50-L/SP90-L Solar Panel User Manual

Page 23

Advertising
background image

SP50-L/SP90-L Solar Panel

TO CHARGER BATTERY (+) TERMINAL

TO LOGGER OR RADIO OR OTHER LOAD (+) TERMINAL

TO CHARGER BATTERY (-) TERMINAL

TO LOGGER OR RADIO OR OTHER LOAD (-) TERMINAL

CHARGE

LOAD

BATTERY

POST

14-Amp FUSE

5-Amp FUSE

CHARGE

LOAD

BATTERY

POST

14-Amp FUSE

5-Amp FUSE

LOAD CHA

RGE

LOAD CH

ARGE

BATTERY TERMINALS

Terminal Strip Bus

Deep Cycle Battery

WIRING DIAGRAM FOR PN 4386 BATTERY TERMINAL BUS

FIGURE 3-19. Battery terminal strip adapters for power connection to

external battery

4. Maintenance

An occasional cleaning of the glass improves the solar panel’s efficiency. If a
problem with the solar panel is suspected, the panel may be checked by
measuring the voltage output. Check the voltage with a voltmeter connected
between the two leads of the solar panel. There must be incident solar
radiation on the panel and there must be a load connected to the solar panel.
The load can be the datalogger, other equipment, or a 75 ohm resistor capable
of dissipating solar panel power between the two leads. No voltage output
implies a bad solar panel, regulator, or cable. The magnitude of the voltage
output depends on the incident solar radiation.

17

Advertising