1 erasing current program, 2 program transfer with storage module, 3 full/half duplex – Campbell Scientific TD Operating System Addendum for CR510, CR10X, and CR23X User Manual

Page 20: 4 set datalogger id, 5 setting powerup options

Advertising
background image

TD ADDENDUM

SECTION 1. FUNCTIONAL MODES

AD-1-4

to which memory is cleared on powerup, to set
the PakBus ID, and to set communication to full
or half duplex.

CSI datalogger support software makes use of the
∗D Mode to upload and download programs from a
computer. Appendix C gives some additional
information on Commands 1 and 2 that are used
for these operations.

When "

∗D" is keyed in, the CR10X will display

"13:00". A command (Table 1.8-1) is entered
by keying the command number and "A".

TABLE 1.8-1.

D Mode Commands

Command

Description

1

Send (Print) ASCII Program

2

Load ASCII Program,

∗0 Compile

2--

Load ASCII Program,

∗6 Compile

3

# Rings Before Answering Phone

7

Erase Current Program

10

Set Powerup Options

12

Set Initial Baud

15

PakBus Address/Routing Table

16

Memory for General Purpose File

17

PakBus Routing Table

18

PakBus Beacon Interval

19

PakBus Neighbor List

If the CR10X program has not been compiled
when the command to save a program is entered,
it will be compiled before the program is saved.
When a program is loaded, it is immediately
compiled and run. When a command is complete,
"13:0000" is displayed;

∗D must be entered again

before another command can be given.

TABLE 1.8-2. Program Load Error Codes

E 94

Program Storage Area full

E 95

Program does not exist in flash

E 96

Storage Module not connected or
wrong address

E 97

Data not encountered within 30 sec.

E 98

Uncorrectable errors detected

E 99

Wrong type of file or Editor Error

1.8.1 ERASING CURRENT PROGRAM

The 7 command may be used to delete the
current program as show in Table 1.8-3.

TABLE 1.8-3 Deleting Current Datalogger

Program

Key entry

Display

∗D

13:00

7A

07:00

You may now enter:

0A

Erase active program (i.e., load a
blank program; memory allocation
and Final Storage are reset).

1.8.2 PROGRAM TRANSFER WITH STORAGE

MODULE

Not supported in Table Data Operating
Systems.

1.8.3 FULL/HALF DUPLEX

Not supported in Table Data Operating
Systems.

1.8.4 SET DATALOGGER ID

Command 8 not supported in Table Data
Operating Systems.

1.8.5 SETTING POWERUP OPTIONS

Setting options for the Program on Powerup
allows the user to specify what information to
retain from when the datalogger was last on.
This allows Flag/Port status, the User Timer,
and the Input/Intermediate Storage to be
cleared or not cleared.

Table 1.8-8. Setting Powerup Options

Key entry

Display

∗D

13:00

10A

10:0X

Where X is the powerup option currently
selected. You may now change the option:

0A

Clears input locations, ports, flags, user

timer, and intermediate storage locations.

1A

Clears intermediate storage only (leaves

Input Storage, Flags/Ports, and User Timer
as is).

2A

Doesn’t clear anything.

Advertising