Section 12. Program Control Instructions

12-13

Location with Seconds Until Transmit

The input location in which to store the number of seconds until it is time to
transmit to the host datalogger.

Use Remote Clock Report (P195)

A program control instruction that sets a remote datalogger's clock based on the
clock value transmitted from the host (or master) datalogger specified by the
address provided in parameter 1.

6: PakBus - Use Remote Clock Report (P195)
1: 0000 Address

Note: This instruction is not used if the datalogger is configured as a wireless
sensor using instruction 196 (Wireless Network Remote). When instruction
196 is used, the remote datalogger will automatically adjust its clock to match
the host (master) datalogger's clock whenever communication is successful.

Address

The unique address for the host (master) datalogger in the PakBus network,
whose clock value will be used to set the clock in the remote datalogger.

The address is set in the datalogger's *D15 mode (refer to the datalogger user's
manual for additional information). It can be any number between 1 and 4095.

Wireless Network Remote (P196)

A program control instruction that is used to set up a remote datalogger to act
as a wireless sensor/controller in a PakBus network.

Communication with the host (master) datalogger is dictated by the host
datalogger. A communication time is assigned to the remote datalogger when
communication is first accomplished with the host. The remote datalogger uses
Instruction 194, Seconds Until Transmit, in conjunction with a conditional
statement to determine when P196 is executed, and therefore, when data is
transferred to the host.

When first installed or when communication is not successful, P194 will
indicate a random interval of up to one second. The remote will try to contact
the master on this interval until communication is successful and it is
programmed with a transmit time.

The remote datalogger's clock is synchronized with the host datalogger's clock,
each time communication between the two dataloggers is successful.

7: PakBus - Wireless Network Remote (P196)
1: 00 Port
2: 0000 Master Address
3: 0000 Security
4: 00 Swath to Receive from Master
5: 0000 First Loc for Data Received [ ______________ ]
6: 00 Swath to Send to Master
7: 0000 First Loc to Send [ ______________ ]
8: 0000 Result Code Loc [ ______________ ]

Advertising