2 wind direction, 3 precipitation, 4 barometric pressure – Campbell Scientific WXT510 Weather Transmitter User Manual
Page 6: 5 air temperature, 6 relative humidity, 7 assembly, Installation, 1 assembling the wxt510
WXT510 Weather Transmitter
2.2 Wind Direction
Measurement Range: 0° to 360°
Accuracy: ±3°
2.3 Precipitation
Rainfall: cumulative accumulation after latest automatic or manual reset.
Accuracy: 5% (Due to the nature of the phenomenon, deviations caused by
spatial variations may exist in precipitation readings, especially in short
time scale. The accuracy specification does not include possible wind
induced error.)
Rain Duration: counting each ten second increment when droplet detected.
Rain Intensity: one minute running average in ten second steps.
2.4 Barometric Pressure
Measurement Range: 600 to 1100 hPa (mbar)
Accuracy: ±0.5 hPa @ 0° to 30°C; ±1 hPa @ -52° to +60°C
2.5 Air Temperature
Measurement Range: -52° to +60°C
Accuracy: ±0.3°C @ +20°C
2.6 Relative Humidity
Measurement Range: 0 to 100% RH
Accuracy: ±3% RH @ 0 to 90% RH; ±5% RH @ 90 to 100% RH
2.7 Assembly
Input Voltage: 5 to 30 Vdc
Typical Current Drain: 3 mA with default measuring intervals
Output: SDI-12
Operating Range: -52° to +60°C; 0 to 100% RH
Dimensions: 9.4" (24.0 cm) height, 4.7" (12.0 cm) diameter
Weight: 1.43 lbs (650 g)
3. Installation
3.1 Assembling the WXT510
1. Lift off the top of the transmitter.
2. Remove the PTU from the plastic bag and insert it into the WXT510 (see
Figures 1 and 2).
3. Replace the top.
4. Tighten the three fixing screws.
2