2 wind direction, 3 precipitation, 4 barometric pressure – Campbell Scientific WXT510 Weather Transmitter User Manual

Page 6: 5 air temperature, 6 relative humidity, 7 assembly, Installation, 1 assembling the wxt510

Advertising
background image

WXT510 Weather Transmitter

2.2 Wind Direction

Measurement Range: 0° to 360°
Accuracy: ±3°

2.3 Precipitation

Rainfall: cumulative accumulation after latest automatic or manual reset.
Accuracy: 5% (Due to the nature of the phenomenon, deviations caused by

spatial variations may exist in precipitation readings, especially in short
time scale. The accuracy specification does not include possible wind
induced error.)

Rain Duration: counting each ten second increment when droplet detected.
Rain Intensity: one minute running average in ten second steps.

2.4 Barometric Pressure

Measurement Range: 600 to 1100 hPa (mbar)
Accuracy: ±0.5 hPa @ 0° to 30°C; ±1 hPa @ -52° to +60°C

2.5 Air Temperature

Measurement Range: -52° to +60°C
Accuracy: ±0.3°C @ +20°C

2.6 Relative Humidity

Measurement Range: 0 to 100% RH
Accuracy: ±3% RH @ 0 to 90% RH; ±5% RH @ 90 to 100% RH

2.7 Assembly

Input Voltage: 5 to 30 Vdc
Typical Current Drain: 3 mA with default measuring intervals
Output: SDI-12
Operating Range: -52° to +60°C; 0 to 100% RH
Dimensions: 9.4" (24.0 cm) height, 4.7" (12.0 cm) diameter
Weight: 1.43 lbs (650 g)

3. Installation

3.1 Assembling the WXT510

1. Lift off the top of the transmitter.

2. Remove the PTU from the plastic bag and insert it into the WXT510 (see

Figures 1 and 2).

3. Replace the top.

4. Tighten the three fixing screws.