2 mounting to a campbell scientific crossarm, Wiring table, Example programs – Campbell Scientific WXT510 Weather Transmitter User Manual

Page 8: 1 cr10x program

Advertising
background image

WXT510 Weather Transmitter

3.2 Mounting to a Campbell Scientific Crossarm

The WXT510 is mounted on a CM202, CM204, or CM206 crossarm via the
18311 mounting pipe and the CM220 bracket. The 18311 pipe is shipped with
the WXT510.

4. Wiring Table

TABLE 1. Connections to Campbell Scientific Dataloggers




Color




Description

CR1000, CR800,
CR850, CR3000,
CR5000,
CR9000(X)



CR10(X),
CR510



21X, CR23X,
CR7




CR200

Brown

Power

12 V

12 V

+12

SW Battery

Clear
(silver)
or Red

Power

ground

G

G G G

Blue

SDI-12

Signal

C1

C2 C2 C1

White

SDI-12

Signal

C1

C2 C2 C1

Green

data ground

G

G G G

Yellow Optional

heater

power (see note)

12V 12V

+12

SW

Battery

Pink Optional

heater

ground (see note)

G

G G G

Grey

Not used

Not used

Not used

Not used

Unless special ordered, the heater will not be operational for
WXT510s purchased from Campbell Scientific. Although the
heater is not operational, the WXT510 will have a pink and
yellow wire. Do not connect the pink and yellow wire unless the
heater is operational.

NOTE

5. Example Programs

5.1 CR10X Program

The following example is the portion of a CR10X program that measures the
WXT510. A complete program will include output processing instructions.

; wind direction wind speed

; Get WXT510 Values 1 - 6 (Dn=Wd min, Dm=Wd avg, Dx=Wd max, Sn=Ws min, Sm=Ws avg, Sx=Ws max)


22: SDI-12 Recorder (P105) ;
1: 0

SDI-12

Address

2: 1

Start

Measurement

(aM1!)

; corresponds with Wind message Command R1

3: 2

Port

; control port for SDI-12 comms

4: 15

Loc [ Value1 ]

5: 1.0

Mult

6: 0.0

Offset

4