B. adjustments, C. lubrication – American Dryer Corp. MLG-130DR (HSI) User Manual

Page 39

Advertising
background image

35

Remove lint accumulation from inside the control box and at rear area behind the control box.

Impellor (fan/blower) shaft bearings should be lubricated using Shell Alvania grease NLGI 2 or its equivalent.

Generically, this grease would be described as an NLGI grade 2 multipurpose industrial grease with a lithium

thickener and mineral base oil.

6 MONTHS

Inspect and remove lint accumulation in customer furnished exhaust duct work system and from dryer’s internal

exhaust ducting.

NOTE: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN

CREATE A POTENTIAL FIRE HAZARD.

NOTE: DO NOT OBSTRUCT THE FLOW OF COMBUSTION and VENTILATION AIR.

CHECK CUSTOMER FURNISHED BACK DRAFT DAMPERS IN THE EXHAUST

DUCT WORK. INSPECT and REMOVE ANY LINT ACCUMULATION WHICH CAN

CAUSE THE DAMPER TO BIND or STICK.

NOTE: A back draft damper that is sticking partially closed can result in slow drying and shut down of

the heat circuit safety switches or thermostats.

NOTE: When cleaning the dryer cabinet(s), avoid using harsh abrasives. A product intended for the

cleaning of appliances is recommended.

B. ADJUSTMENTS

7 DAYS AFTER INSTALLATION and EVERY 6 MONTHS THEREAFTER

Inspect bolts, nuts, screws, (bearing set screws), nonpermanent gas connections (i.e., unions, shut-off valves,

orifices), and grounding connections. Fan (impellor) V-belts, along with the motor and drive chains should be

examined and replaced if necessary. Tighten loose V-belts when necessary. Complete operational check of

controls and valves. Complete operational check of ALL safety devices (i.e., door switches, lint drawer switch,

sail switch, burner and hi-limit thermostats).

C. LUBRICATION

The fan shaft bearings should be lubricated every three (3) months. Use Shell Alvania grease NLGI grade 2 or

its equivalent. Generically, this grease would be described as an NLGI grade 2 multipurpose industrial grease

with a lithium thickener and mineral base oil. Lubrication is necessary. The motor bearings...and under normal/

most conditions the tumbler bearings are permanently lubricated. It is physically possible to re-lubricate the

tumbler bearings if you choose to do so even though this practice may not be necessary. Use Shell Alvania

grease NLGI grade 2 or its equivalent. Generically, this grease would be described as an NLGI grade 2 multipurpose

industrial grease with a lithium thickener and mineral base oil. The tumbler bearings used in the dryer DO NOT

have a grease fitting. Provisions are made in the bearings housing for the addition of a grease fitting which can

be obtained elsewhere, or from ADC by ordering kit P/N 882159 (includes 2 fittings).