AVerMedia Technologies EB1304 User Manual

Page 23

Advertising
background image

19

OSD MENU

Description

2006 / 12 / 11
17 : 54 : 50
ON
ON

ON
OFF

NO

SUBMENU
PASSWORD CHANGE
VIDEO ADJUSTMENT
DATE
TIME
AUTO RECORD
AUTO SCAN
PASSWORD SETUP
AUDIO RECORD
AUDIO MUTE

NTSC

ON

VIDEO SYSTEM
TEMERATURE SET
BUZZER

TEMPERATURE SET:

Set the DVR unit temperature type and high/low
threshold limit.

040
050
005

050

TEMPERATURE SET
TEMPERATURE TYPE
HIGH THRESHOLD
LOW THRESHOLD
DVR HOT PROTECT
DVR COLD PROTECT

CENTIGRADE

TEMPERATURE TYPE:

Temperature pattern display on front LED panel.

HIGH THRESHOLD:

Set a specific temperature limited for fan active. When
the hard disk temperature is higher than limited
temperature, the fan will be active. The default value is
50

°C.

LOW THRESHOLD:

Set a specific temperature limited for fan stop. When
the hard disk temperature is lower than limited
temperature, the fan will be stop. The default value is
45

°C.

DVR HOT PROTECT:

Set the temperature limit to shutdown hard disk when
the DVR unit temperature is higher than (>) limited. The
default value is 60

°C.

DVR COLD PROTECT:

Set the temperature limit to stop recording when the
DVR unit temperature is lower than (<) limited. The
default value is 5

°C.

BUZZER:

Enable/disable system buzzer sound. The default
setting is ON.

Status

Sound

System Power ON

One long buzz sound

Video Loss

Continue long buzz sound

Fan stop/broken

Continue short buzz sound

Hard Disk is Full

Three Long buzz sound

Advertising