OSD MENU

Description

010 SEC
010 SEC
NOT INSTALLED
NOT INSTALLED
NOT INSTALLED
NOT INSTALLED

SENSOR SETUP
SENSOR REC TIME
ALARM OUT TIME
CHANNEL - 1
CHANNEL - 2
CHANNEL - 3
CHANNEL - 4

SENSOR REC TIME :

Set the amount of time (in second) to record when the
sensor has been triggered.

ALARM OUT TIME :

Set the amount of time (in second) to continue sending
the alarm once activated.

CHANNEL 1~4 :

Customize the initial state of the attached sensor. Refer
to the table below to customize the sensor state.

Condition

Description

NOT INSTALLED

Indicates that there is no sensor connected.

NORMAL OPEN

Indicates that the initial state of the sensor is
normal open. Video recording initiate when
there is a change in the sensor state.

NORMAL CLOSE

Indicates that the initial state of the sensor is
normal close. Video recording initiate when
there is a change in the sensor state.

1

2

3

4

5
010 SEC

MOTION SETUP
MOTION CAMERA
SENSITIVITIY
MOTION RECORD TIME

MOTION CAMERA :

Enable/disable the channel number to detect motion.

SENSITIVITY :

Set the sensitivity level. The sensitivity is from high, 9~
2 and low.

MOTION RECORD TIME :

Set the amount of time (in second) to record when a
motion is detected.