AR-6G Rotisserie Operation & Care Manual • 14

I n s t a l l a t I o n

AR-6G Rotisserie Operation & Care Manual • 14

G a s e x h a U s t

The appliance is not to be directly connected to a chimney

vent system nor directly connected to a horizontal exhaust

system. The unit must be installed under a ventilation hood

listed as ANSI/UL 705 (latest edition), and the installation

must be conducted in accordance with the ANSI/NFPA 96-

1987, Standard for Ventilation Control and Fire Protection

of Commercial Cooking Operations.

Operators of the appliance should be instructed not to

place any material on top of the appliance that would

obstruct the flow of flue products from the opening.

Operators should also be instructed that flue gases are hot

and any material or items placed on top or in front of the

flue defector could be damaged or cause a fire hazard.

I G n I t I o n s y s t e m

This unit is equipped with "direct spark ignition" for ease

of lighting the burners.

The electrodes are located just above the burner under

the burner cover on the right hand side of the appliance.

These electrodes are very fragile and care must be taken

if adjustment is required. Special care must be used to

prevent breakage of the porcelain insulator.

If the porcelain is damaged or broken, the igniter assembly

must be replaced. The end of the electrode must have a

gap of 1/8" to 3/16" (3mm to 5mm) from the top surface

of the burner. The spark must be maintained between the

electrode and the burner for proper ignition.

l e a K t e s t I n G

If a pressure leak test above 1/2 psi is to be conducted on

the building supply gas piping, the shutoff gas valve and

appliance inlet gas supply line must be disconnected from

the building supply piping before conducting the pressure

test. Failure to do so may result in damage to the manual

gas valve and/or gas components in the appliance.

If any gas leak tests are to be conducted at pressures equal to

or below 1/2 psi, the manual gas shut off valve upstream of

the appliance must be turned off before conducting the tests.

Leak testing of the internal appliance piping system was

conducted before shipping the appliance from the factory.

If additional testing is needed, it should only be conducted

at normal gas supply pressures. If the testing is performed

using combustible gas in the piping, leak testing should

be done with a soap solution (bubble checking) or other

approved liquid.

The use of an electronic combustible gas leak detector is

helpful; however, this type of detector can be oversensitive.

Electronic detectors may indicate false leaks from other

sources which would not be detected when checking with

a liquid solution to verify a no-hazard gas connection.

When starting the appliance after initial installation, the gas

lines must be free of air which may take up to 30 minutes to

purge from supply line. If the burners do not light after this

period of time, call factory for assistance.

D a n G e r

neVer Use an open

flame to leaK test.

D a n G e r

before startInG the
applIance, maKe certaIn
yoU Do not Detect the
oDor of Gas.

IF THE ODOR OF GAS IS DETECTED:
• DO NOT attempt to light any appliance.
• DO NOT touch any electrical switches.
• Extinguish any open fl ame.
• Use a telephone OUTSIDE THE

PROPERTY & IMMEDIATELY
contact your gas supplier.

• If unable to contact your gas supplier,

contact the fi re department.