15

Operation

F232061

Display Indications

Display

Meaning

Display

Meaning

FC 5

Program identification code (ROM). This
is an example only.

HFIL

Hot fill

Lo

Low water level

Hold

Wait...power has just been turned on.

n

ed

Medium water level

PAY/(price)*

Pay (flashes alternately with start price if
“FLSH” SETUP option is enabled)

HI

High water level

SUP0

No supplies

CY

Cycle (followed by two-digit number)

SUP1

Supply 1

tESt/CYC*

Test cycle selected.

SUP2

Supply 2

FAr

Degrees Fahrenheit

SUP3

Supply 3

CEL

Degrees Celsius

SUP5

Supply 5 (Supply 1 and 2)

Heat

Auxiliary heat enabled.

SUP6

Supply 6 (Supply 2 and 3)

noHt

Auxiliary heat disabled.

drAI/dISt*

Distribution (load balancing before extract)

FLSH

Flashing vend price enabled.

drAI/For*

Drain step (low speed forward in test
cycle)

nFLS

Flashing vend price disabled.

SPIn/tI

n

E*

Reads “SPIn” for one second, then

“tI

n

E” followed by time for spin.

Strt/A

n

t*

Start amount—flashes briefly before
showing vend price in SETUP mode

SdLY

Spin coast delay

Con1/deno*

Coin 1 value—flashes briefly before
showing value of coin 1 in SETUP mode

STOP

Stop routine

donE

Cycle and stop routine have ended.

Con2/deno*

Coin 2 value—flashes briefly before
showing value of coin 2 in SETUP mode

HI 1

Low spin in test cycle.

HI 2

High spin in test cycle.

PrE

Prewash segment (1st of 8 segments)

bAL/FAIL*

Balance routine failed during test cycle.

UASH

Wash segment (2nd of 8 segments)

SHUT/door*

Door not properly closed.

FIL1

First fill (3rd of 8 segments)

CANt/OPEN*

Computer cannot unlock door after five
attempts.

FIL2

Second fill (4th of 8 segments)

FIL3

Third fill (5th of 8 segments)

FILL/STOP*

Programmed water level not reached after
30 minutes.

FIL4

Fourth fill (6th of 8 segments)

FIL5

Fifth fill (7th of 8 segments)

FULL

The computer detects low water level or
higher when none should be present.

FIL6

Sixth fill (8th of 8 segments)

AFIL

Auxiliary fill

dFLt

Drive fault detected.

bFIL

Warm fill (both hot and cold)

tSFL

Temperature sensor failure or temperature
out of range.

CFIL

Cold fill

bLCH

Add bleach

*Display indications separated by a slash represent an alternating display.