Monitoring with an ASCII Terminal

Campus-REX RS Interface Card User Manual

6-3

2

Type

then press

. The Current System Status menu displays.

The Current System Status menu provides the following information:

•

Local Alarms indicates the current local alarm status

•

Remote Alarms indicates the current remote alarm status

•

Loopback indicates the current loopback status

•

Margin indicates the minimum (mn), current (cr), and maximum (mx)
HDSL margin value, measured in dB, relative to the signal-to-noise ratio
required for a Bit Error Rate (BER) of 10

-7

•

Pulse Attn indicates the decrease in amplitude of the transmitted signal
as measured at the HDSL receiver

•

24 Hour ES indicates the number of errored seconds over the last
24 hours

•

24 Hour UAS indicates the number of unavailable seconds over the last
24 hours

•

Last Cleared indicates the date and time when the error counter was last
cleared

1

ENTER

May 3, 1999

ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx

13:14:35

Local Unit ID:

Campus-REX Unit #34

Local I/F:

REX

Remote Unit ID: Campus-REX Unit #12

Remote I/F: REX

Circuit ID:

Network Extension Circuit 5001

CURRENT SYSTEM STATUS

Local

Alarms:

Remote Alarms:

Loopback: None

HDSL-A

HDSL-B

LOCAL

REMOTE

LOCAL

REMOTE

--------

--------

--------

--------

mn/cr/mx

mn/cr/mx

mn/cr/mx

mn/cr/mx

Margin (dB):

na/na/na

na/na/na

na/na/na

na/na/na

Pulse Attn (dB):

00

00

00

00

24 Hour ES:

00000

00000

00000

00000

24 Hour UAS:

05671

00000

05671

00000

Last Cleared:

None

(U)pdate

(C)lear

(R)eturn

(M)ain Menu

ENTER CHOICE>

CAD1069i5.book Page 3 Thursday, May 30, 2002 7:32 AM