Technical specifications – Acer AN1600 User Manual

Page 7

Advertising
background image

7

Acer AN1600 F1 Network Storage System Specifications

Technical Specifications

Dimensions
(with bezel)

438.4 mm (W) x 705 mm (D) x 88.1 mm (H) ( 17.3 x 27.8 x 3.5 inches)

Form factor

2U rack mount (with cable arms included)

Weight
(approximate)

Maximum
(All component slots and sockets
fully populated)

38 kg (84 lbs.)

Minimum
(One HDD, power supply, and
processor installed)

27.5 kg (60.6 lbs.)

BTU rating

Maximum

2456.64 BTU/hr.

System inlet
temperature

Operating

0° - 35°C (50° - 95°F) at sea level with an altitude
derating of 1°C per 305 m (1.8°F per 1000 ft.)
above sea level to a maximum of 3050 m (10,000
ft.) with no direct sustained sunlight. Maximum rate
of change is 10°C/hr. (18°F/hr.). The upper limit
depends on the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).

Non-operating

-40° - 70°C (-40° - 158°F) maximum rate of change
is 20°C/hr. (36°F/hr.).

Relative humidity
(non-
condensing)

Operating

8 - 90 % relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-condensing

Non-operating

5 - 95 % relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-condensing

Emissions
classification
(EMC)

FCC rating

Class A


Normative standards


EN55022, EN 61000-3-2, EN 61000-3-3, CISPR
22 Class A

Power supply

Rated steady-state power

720 W (at 100 VAC)

720 W (at 200 VAC)

Maximum peak power

720 W (at 100 VAC)

720 W (at 200 VAC)