Installation, For qualified installers only), Mobile home requirements – Avalon Stoves Arbor PS User Manual

Page 11: Outside air (used for combustion)

Advertising
background image

Installation

(For Qualified Installers Only)

1 1

© Travis Industries

4070806

1 0 0 - 0 1 1 9 1 _ 0 0 0

Mobile Home Requirements

•

Outside air is required (used for
combustion) - see the directions
below.

•

The heater must be bolted to the
floor (Some states do not require
this; check with your local building
department). See the illustration
to the right.

•

The heater must be grounded to
the steel chassis of the mobile
home (Some states do not require
this; check with your local building
department).

WARNING:

DO NOT INSTALL IN
SLEEPING ROOM.

CAUTION:

THE STRUCTURAL
INTEGRITY OF THE
MANUFACTURED HOME
FLOOR, WALL, AND
CEILING/ROOF MUST BE
MAINTAINED.

The leveling bolts in the legs may be used

in conjunction with the included clips (sku

210-03924) to secure the stove to the floor.

Outside Air (used for combustion)

•

Must not be drawn from an enclosed space (garage, unventilated crawl space).

HINT:

Travis Industries strongly suggests outside air for all residential installations, especially for
those that are energy efficient, air-tight homes.

•

Must not be over 15' long.

•

Must be made with 3" diameter or larger metal or aluminum duct with a metal screen attached to
the end to keep out rodents (P.V.C. or other combustible materials may not be used). We
recommend the Travis Industries Outside Air Kit (part # 99200136).

•

Must not terminate above or within 1' of the chimney termination.

•

Must have a rain cap or down-turned elbow to prevent water from entering.

•

Must be located so that it will not become plugged by snow or other material.

3” Air Duct

(99200136 includes 4’ length)

A screen is required to prevent

rodents from entering.

Outside air entrance must be placed so it

does not become blocked by snow.

Air may be drawn from a ventilated crawl space.

Botttom of Stove

Use a hose clamp to secure the

aluminum air duct to the air inlet

flange on the stove.

Air Duct (3” Dia.)