2 unpacking and inspection, 3 osp fiber cable installation guidelines, Unpacking and inspection – ADC 19717-A User Manual

Page 17: Osp fiber cable installation guidelines

Advertising
background image

ADCP-75-169 • Issue 1 • June 2004

Page 9

© 2004, ADC Telecommunications, Inc.

4.2

Unpacking and Inspection

This section provides instructions for opening the shipping boxes, verifying that all parts have
been received, and verifying that no shipping damage has occurred. Use the following
procedure to unpack and inspect the HU and any accessories:

1. Open the shipping cartons and carefully unpack each component from the protective

packing material.

2. Check each component for broken or missing parts. If there are damages, contact ADC

(see section 6 at the end of this manual) for an RMA (Return Material Authorization) and
to reorder if replacement is required.

4.3

OSP Fiber Cable Installation Guidelines

The outside plant (OSP) fiber optic cables should be routed between the HU and RU and
terminated before the equipment is installed. A diagram of a typical OSP cable routing is shown
in

Figure 8

. At the HU, the OSP cable should be terminated at a fiber distribution panel and

spliced to pigtails. Jumper patch cords may then be used to link the HU optical ports to the OSP
cable terminations. Whenever possible, a guideway such as the FiberGuide system should be
provided to protect the fiber optic patch cords from damage and to prevent excessive bending.
The procedures for connecting the OSP cable optical fibers to the HU is provided in

Section 4.8

.

Figure 8. Typical Fiber Optic Cable Routing

HOST UNIT

FIBER DISTRIBUTION

PANEL

X

STM

OUTDOOR

REMOTE SITE

HOST SITE

PATCH

CORDS

PATCH

CORDS

SPLICE

SPLICE

ENCLOSURE

INDOOR/OUTDOOR

CABLE WITH

PIGTAIL LEADS

OUTSIDE PLANT

CABLE

OUTDOOR

CABINET

18626-B

INDOOR

REMOTE SITE

STM

X

INDOOR

MOUNTING

SHELF

FIBER DISTRIBUTION

PANEL

X

TERMINATION

X