Allied Telesis AR750S-DP Secure VPN Router User Manual

Page 13

Advertising
background image

AR750S-DP Secure VPN Router

12

1. Check that the power supply and cable is not live.

Ensure the circuit breaker for the supply circuit is in the off position, and the
PSU run/standby button is in the standby position. When the run/standby
button is not depressed, it is in standby.

2. Plug the supply cable into the router.

Plug the provided DC power cord into the power inlet on the faceplate of
the PSU. The plug is keyed with locking tabs, and will only fit in the inlet one
way. The following figures show the polarity of the supply cable and the
power inlet.

3. Secure the cable.

Secure the supply cable to the rack framework or a similar object, to ensure
that the connections are isolated from any force applied to the cable.

12

3

black

wire

Top view of DC plug

blue
wire

DC_Cable

red
wire

40-60VDC , 2.0A

negative

earth

run/standby
button

positive

DC_input

Advertising