Allied Telesis x610 Series Layer 3 User Manual
Page 104

2205
A
A
A
T
-PWR250
DC OUT
FAULT
+
-
6A
40-60VDC
FOR CENTR
ALIZED DC POWER
C
ONNECTION,
INST
ALL ONL
Y IN A
ON
OFF
+48 VDC Positive
Ground
-48 VDC Negative
Terminal
Terminal
Terminal
8mm ±1mm
(0.31in. ±0.039in.)
Chapter 4: Cabling the Network Ports
104
Figure 71. DC Terminal Block on the DC AT-PWR250 Power Supply
Module
4. With a 14-gauge wire-stripping tool, strip the three wires in the tray
cable coming from the DC input power source to 8mm
± 1mm (0.31 in.,
± 0.039 in.), as shown in Figure 72 on page 104.
Warning
Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation. E10
Figure 72. Stripped Wire
5. Insert the power supply ground wire into the middle connector of the
DC terminal and tighten the connection with a flathead screwdriver, as
shown in Figure 73 on page 105.